Part Number
Once your search is narrowed to one product,
the corresponding part number is displayed here.
Part Number | — | Nominal |
FENL4 | — | 1 |
Part Number | T | A | B | E | |
Type | Applicable Tube O.D. (mm) | ||||
FETBS | 4 | 4 | 10 | 3 | 2 |
6 | 6 | 12 | 4 | 2.5 | |
8 | 8 | 16 | 6 | 4.3 | |
10 | 10 | 20 | 8 | 6.8 |
3D preview is not available, because the part number has not yet been determined.
Loading...
Applicable Fluid | Super Pure Water, Acid, Alkali, Organic Solvent |
Operating Temperature Range | 0 to 100°C |
Max. Operating Pressure | Nominal Dia. 4 to 8: 0.8 MPa Nominal Dia. 10: 0.6 Mpa |
Tube size mm | Tightening Torque | Number of Revolution | ||
N⋅m | kgf・cm | |||
4 × 3 | — | 0.12 | 1.2 | 1 |
6 × 4 | 6.35 × 4.3 | 0.23 | 2.3 | 1-1/4 |
8 × 6 | — | 0.45 | 4.6 | 1-1/4 |
10 × 8 | 9.53 × 6.3 | 0.8 | 8.2 | 1-1/2 |
(*) 1. PFA tube is used in the measurement.
2. General tolerance of tube is absorbed if the nut is tightened by the above torque value.
3. Number of revolution is begun to count up when tightening becomes fixed suddenly after lightly tightened by hand.
Type | Related Components | Main Body Material | Fluororesin | Type of Related Component | Tube Insert |
---|---|---|---|---|---|
Maximum Operating Temperature(℃) | 100 |