Drivers for Motor-Integrated Type Conveyors

Drivers for Motor-Integrated Type Conveyors
[Features] This is a driver for conveyors with built-in motor. -Compatible conveyor (No.) is CVSMB.

Part Number

Once your search is narrowed to one product,
the corresponding part number is displayed here.

FCDR

FCDR
Driver for Motor Integrated Conveyor: Related Image

Specification Table

● Connections
Driver for Motor Integrated Conveyor: Related Image


■ Specifications

ItemDescription
Compliant
Motor
Part NumberTCP-S27A-611B
Magnet Pole SensorHall IC (Square-wave Output)
Power Supply Voltage24 V DC within ±10% (12 V DC within ±10%)
Control Circuit Power Consumption1W or less
Rated Output Current *1280 mA
Overload Current340 mA
Current Limit Value2.2 A
PWM FrequencyApprox. 20.0 KHz
Speed Variable Range *2200 to 6,900rpm
External Speed Command Factor1,500rpm/V
Speed Setting
(Rotation Speed Setting)
Internal Driver Settings: 2 systems of RV1 and RV2 (can be switched by speed switch input) External Speed Command Input: 1 System
Soft Start
Setting *4
Can be configured as 1.67 sec/1,000 rpm Max. with RV3
Works at startup and speed increase by speed command (D1 blinking when working)
Protective Function *5Overload: Shuts off the output to retain the state if the current exceeding the rated output has flown continuously.
(Reset by start input "Open" and power-on again)
Sensor Error: Shut off the output by detecting an error code of the sensor signals
(Reset by start input "Open" and power-on again)
Motor Restrained: Shut off the output by detecting motor lock
(Reset by start input "Open" and power-on again)
Overcurrent: Shut off the output by detecting abnormal motor current
Fuse Protection: Shut off the circuit by detecting abnormal power current
Operating Environment0 to 40°C, 85% RH or less (No Condensation)
To be used in the atmosphere with thermal convection
Storage Environment−10 to 60°C, 85% RH or less (No Condensation)
AccessoryMotor Connection Cable (50 cm)
Power Supply / Control Signal I/O Cable (50 cm)
MassApprox. 30g (Main Body only)


■Input / Output Signal

Name, Pin No.Line ColorSignal NameDetails
CN1
(Power Supply, Control Signal I/O)
1BrownStart Input"H": Stop, Alarm Reset
"L": Rotating Operation
"H": Open
"L": 0 to 0.7 V
Input Current: 3mA MAX
2RedRotating Direction Switch Input"H": CW Rotation
"L": CCW Rotation
3OrangeBrake
Selection Input
Select the stop method when the start input switches to "H"
"H": Select Free-run Stop
"L": Select Brake Stop
4YellowSpeed Switch Input"H": Select RV1
"L": Select RV2
5GreenRotation Synchronization Signal OutputOutput 6 pulse / rotation signal synchronized with the rotationOpen-collector output
Max. Applied Voltage: 30 V
Max. Current: 20 mA
Saturation Voltage at Power ON: 0.8 V MAX
Built-in Free Wheel Diode
6BlueAlarm OutputOutput transistor turns ON when detecting overload, sensor error, overcurrent
Output transistor is OFF during normal state
7PurpleExternal Speed
Command Input *6
Input Voltage: 0 to 5 V (10 V MAX)
Input Impedance: 10 KΩ or more
8GrayGNDGround for Control Input Signal (Same potential as CN1-10)
9WhitePower Input+24V Input
10Black0V Input (Same potential as CN1-8)
CN2
(Motor Signal I/O)
8Red+5 V5V Output for Magnet Pole Sensor (Cannot be used for other applications)
6BlackGNDGOD for Magnet Pole Sensor
12BrownSensor Signal InputA Phase
11Unused
10YellowB-phase
4Unused
1WhiteC-phase
2Unused 
5BlueMotor OutputA-phase Coil
7GreenB-phase Coil
3OrangeC-phase Coil
9NCUnused
Status Display LEDReady Display
LED (D1: Green)
Ready State (Drive-Ready): Light ON
Soft Start Operation: Blinking
Error: Light OFF
Error Display
LED (D2: Red)
Normal Operation: Light OFF
Power-on Reset: Light ON (0.5 Sec.)
Current Exceeding Overload Detected: Light ON
Sensor Error: Continuous Lighting
Motor Lock Detected: Blinks Once
Overload Detected: Blinks Twice
Blown Fuse
LED (D3: Red)
Turns ON when Fuse blown
Adjustment VRRV1*6Speed Setting SP1 (Set to 0 at the time of shipping)
RV2*6Speed Setting SP2 (Set to 0 at the time of shipping)
RV3Soft Start Setting SOFT (Set to 0 at the time of shipping)

*1: The rated output current is the continuous allowable current when combined with a supported motor.
Be sure to use it at a current equal to or lower than the allowable current (allowable torque) for the geared motor you use.
*2: The maximum value of the speed variable range is proportional to the power voltage. The value listed here is the no-load rotation speed at 24 V input.
*3: This driver has second quadrant operations and cannot be used for applications with gravity load applied.
*4: The soft start function only works during acceleration and does not work during deceleration.
*5: Be sure to perform resetting after removing the cause when the protection function is activated.
*6: For the motor rotation speed, the highest setting value among RV1, RV2, and the speed command input takes precedence.
To use the external speed command input, set RV1 and 2 to 0. To use the internal speed setting, set the external speed command input to Open or 0V.

Part Number:  

    3D preview is not available, because the part number has not yet been determined.

  • In order to open the 3D preview, the part number must be fixed.
Loading...
Part Number
FCDR
Part Number
Standard Unit Price
Minimum order quantityVolume Discount
Standard
Shipping Days
?
RoHS

112.48 €

1 12 Days 10

Loading...

  1. 1

Basic information

Type Driver Only Compatible Conveyors (No.) CVSMB

This page is Drivers for Motor-Integrated Type Conveyors, part number FCDR.
You can find the detail information about specifications and dimensions on part number FCDR.

MISUMI Unit еxample related to this product